{"id":11010,"date":"2026-03-12T11:25:35","date_gmt":"2026-03-12T00:25:35","guid":{"rendered":"https:\/\/tristel.com\/au-en\/latest-news\/\/"},"modified":"2026-11-05T14:51:26","modified_gmt":"2026-11-05T03:51:26","slug":"understanding-material-and-device-compatibility","status":"publish","type":"post","link":"https:\/\/tristel.com\/au-en\/latest-news\/understanding-material-and-device-compatibility\/","title":{"rendered":"Material compatibility and efficacy validation: choosing the right reprocessing products for your medical device"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div lang=\"en-AU\" style=\"position:relative;overflow:hidden;background:#f4e8f2;border-radius:20px;padding:26px 32px 30px;margin:0 0 32px\"><img decoding=\"async\" src=\"https:\/\/tristel.com\/wp-content\/uploads\/2026\/07\/Is-wiping-as-effective-as-traditional-soaking-for-endoscope-disinfection-.png\" alt=\"\" aria-hidden=\"true\" style=\"position:absolute;top:0;right:0;bottom:0;left:auto;z-index:0;display:block;width:68%;height:100%;max-width:none;max-height:none;margin:0;padding:0;border:0;border-radius:0;box-shadow:none;object-fit:cover;object-position:center 35%;opacity:0.22;pointer-events:none\"\/><span aria-hidden=\"true\" style=\"position:absolute;top:0;right:0;bottom:0;left:0;z-index:0;display:block;background:linear-gradient(90deg,#f4e8f2 0%,#f4e8f2 34%,rgba(244,232,242,0.6) 52%,rgba(244,232,242,0) 72%);pointer-events:none\"><\/span><div style=\"position:relative;z-index:1\"><div style=\"display:flex;flex-wrap:wrap;align-items:flex-start;justify-content:space-between;gap:16px;margin:0 0 16px\"><a href=\"https:\/\/tristel.com\/au-en\/latest-news\/categories\/ipc-in-practice\/\" style=\"display:block;text-decoration:none;max-width:420px\"><span style=\"display:flex;align-items:center;gap:10px\"><img decoding=\"async\" src=\"https:\/\/tristel.com\/wp-content\/uploads\/2026\/09\/TRI_Academy_Shapes_Academy_Square_Purple.svg\" alt=\"\" style=\"display:block;width:18px;height:18px;margin:0;flex:0 0 18px\"\/><span style=\"font-size:12px;font-weight:600;letter-spacing:0.18em;text-transform:uppercase;color:#17223c\">IPC in Practice<\/span><\/span><\/a><\/div><p style=\"margin:0 0 18px;font-size:20px;font-weight:500;line-height:1.3;color:#17223c\">In this article you&#8217;ll <span style=\"position:relative;display:inline-block;font-family:&apos;Playwrite NZ&apos;,cursive;font-weight:400;font-size:1.05em;line-height:1.35;color:#17223c;padding:0 2px 8px 2px\">learn<img decoding=\"async\" src=\"https:\/\/tristel.com\/wp-content\/uploads\/2026\/09\/Tristel-Academy-Linkedin-Post-Templates-105-x-105-mm-1.png\" alt=\"\" style=\"position:absolute;left:-4%;top:100%;width:108%;height:18px;max-width:none;margin:-9px 0 0 0;border:0;box-shadow:none\"\/><\/span><\/p><ul style=\"display:flex;flex-wrap:wrap;gap:14px 28px;margin:0;padding:0\"><li style=\"flex:1 1 270px;display:flex;gap:12px;align-items:flex-start;margin:0;padding:0;font-size:15px;line-height:1.5;color:#17223c\"><span style=\"display:inline-flex;flex:0 0 12px;width:12px;height:12px;background:#951b81;border-radius:2.2px;margin-top:5px\"><\/span><span>What is material compatibility?<\/span><\/li><li style=\"flex:1 1 270px;display:flex;gap:12px;align-items:flex-start;margin:0;padding:0;font-size:15px;line-height:1.5;color:#17223c\"><span style=\"display:inline-flex;flex:0 0 12px;width:12px;height:12px;background:#951b81;border-radius:2.2px;margin-top:5px\"><\/span><span>What is efficacy validation?<\/span><\/li><li style=\"flex:1 1 270px;display:flex;gap:12px;align-items:flex-start;margin:0;padding:0;font-size:15px;line-height:1.5;color:#17223c\"><span style=\"display:inline-flex;flex:0 0 12px;width:12px;height:12px;background:#951b81;border-radius:2.2px;margin-top:5px\"><\/span><span>What makes chemistry compatible with a medical device?<\/span><\/li><li style=\"flex:1 1 270px;display:flex;gap:12px;align-items:flex-start;margin:0;padding:0;font-size:15px;line-height:1.5;color:#17223c\"><span style=\"display:inline-flex;flex:0 0 12px;width:12px;height:12px;background:#951b81;border-radius:2.2px;margin-top:5px\"><\/span><span>The power of chlorine dioxide<\/span><\/li><\/ul><\/div><\/div>\n<p lang=\"en-AU\" style=\"font-size:21px;line-height:1.55;font-weight:400;color:#17223c;margin:0 0 28px\">When selecting reprocessing solutions for your medical device, it is important to choose products that are both compatible and effective.<\/p>\n<p lang=\"en-AU\">Material compatibility ensures that the disinfectant and the device work safely together. If a disinfectant is not compatible with the device materials, it can cause damage ranging from cosmetic changes, such as discolouration, to surface alterations like stickiness, or even material degradation that may impact device performance and patient safety.<\/p>\n<div lang=\"en-AU\" aria-hidden=\"true\" style=\"background:#ffffff;border-radius:16px;padding:22px 24px 20px;margin:0 0 28px\"><div style=\"height:8px;border-radius:8px;background:linear-gradient(90deg,#e8cfe3 0%,#951b81 70%,#17223c 100%);margin:0 0 16px\"><\/div><div style=\"display:flex;flex-wrap:wrap;gap:12px 20px\"><div style=\"flex:1 1 180px;min-width:0\"><p style=\"margin:0 0 2px;font-size:15px;font-weight:600;line-height:1.4;color:#17223c\">Cosmetic changes<\/p><p style=\"margin:0;font-size:14px;line-height:1.5;color:#454861\">such as discolouration<\/p><\/div><div style=\"flex:1 1 180px;min-width:0\"><p style=\"margin:0 0 2px;font-size:15px;font-weight:600;line-height:1.4;color:#17223c\">Surface alterations<\/p><p style=\"margin:0;font-size:14px;line-height:1.5;color:#454861\">like stickiness<\/p><\/div><div style=\"flex:1 1 180px;min-width:0\"><p style=\"margin:0 0 2px;font-size:15px;font-weight:600;line-height:1.4;color:#17223c\">Material degradation<\/p><p style=\"margin:0;font-size:14px;line-height:1.5;color:#454861\">that may impact device performance and patient safety<\/p><\/div><\/div><\/div>\n<p lang=\"en-AU\">At the same time, it is essential to use products that provide the required level of cleaning and disinfection for the intended application, ensuring the device is safe for patient use.<\/p>\n<div lang=\"en-AU\" style=\"margin:20px 0 36px\"><p style=\"margin:0 0 14px;font-size:14.5px;line-height:1.6;color:#454861\">Let&#8217;s look at these two requirements in more detail.<\/p><div style=\"display:flex;flex-wrap:wrap;gap:12px\"><a href=\"#what-is-material-compatibility\" style=\"flex:1 1 250px;display:block;padding:20px 22px 18px;border-radius:16px;background:#17223c;text-decoration:none\"><span style=\"display:block;font-size:12px;font-weight:600;letter-spacing:0.12em;text-transform:uppercase;color:#c4c2d0\">Requirement 1<\/span><span style=\"display:block;margin:4px 0 16px;font-size:18px;font-weight:600;line-height:1.35;color:#ffffff\">Material compatibility<\/span><span style=\"display:inline-flex;align-items:center;gap:10px;font-size:14px;font-weight:600;color:#ffffff\"><span aria-hidden=\"true\" style=\"flex:0 0 30px;width:30px;height:30px;border-radius:50%;background:linear-gradient(90deg,rgb(149,27,129),rgb(215,11,82));color:#ffffff;font-size:15px;line-height:30px;text-align:center\">&#8595;<\/span><span style=\"text-decoration:underline\">Jump to section<\/span><\/span><\/a><a href=\"#what-is-efficacy-validation\" style=\"flex:1 1 250px;display:block;padding:20px 22px 18px;border-radius:16px;background:#17223c;text-decoration:none\"><span style=\"display:block;font-size:12px;font-weight:600;letter-spacing:0.12em;text-transform:uppercase;color:#c4c2d0\">Requirement 2<\/span><span style=\"display:block;margin:4px 0 16px;font-size:18px;font-weight:600;line-height:1.35;color:#ffffff\">Efficacy validation<\/span><span style=\"display:inline-flex;align-items:center;gap:10px;font-size:14px;font-weight:600;color:#ffffff\"><span aria-hidden=\"true\" style=\"flex:0 0 30px;width:30px;height:30px;border-radius:50%;background:linear-gradient(90deg,rgb(149,27,129),rgb(215,11,82));color:#ffffff;font-size:15px;line-height:30px;text-align:center\">&#8595;<\/span><span style=\"text-decoration:underline\">Jump to section<\/span><\/span><\/a><\/div><\/div>\n<span lang=\"en-AU\" id=\"what-is-material-compatibility\" aria-hidden=\"true\" style=\"display:block;position:relative;top:-160px;height:0;margin:0;padding:0;visibility:hidden\"><\/span><h2 lang=\"en-AU\" style=\"color:#17223c;max-width:none;width:auto\">What is material compatibility?<\/h2>\n<div lang=\"en-AU\" style=\"display:flex;flex-wrap:wrap;align-items:center;gap:20px 32px;margin:0 0 36px\"><div style=\"flex:1 1 320px;min-width:0\"><p>Material compatibility refers to how different materials interact with specific chemicals. Depending primarily on the composition and physical properties of the material, other factors include the mode of action, concentration and exposure conditions of the disinfectant.<\/p><p style=\"margin-bottom:0\">Overall, material compatibility needs to reflect a medical device&#8217;s individual material&#8217;s ability to withstand exposure to cleaning agents and disinfectants without compromising its functionality.<\/p><\/div><figure style=\"flex:0 1 360px;width:360px;max-width:100%;margin:0 auto;padding:0\"><img decoding=\"async\" src=\"https:\/\/tristel.com\/wp-content\/uploads\/2025\/09\/device_edited-edited.jpg\" alt=\"Ultrasound probe being wiped with a disinfectant wipe, where material compatibility matters\" style=\"display:block;width:100%;height:auto;aspect-ratio:4\/3;object-fit:cover;object-position:center;margin:0;border-radius:20px;border:0;box-shadow:none;background:#e5e4f2\"\/><\/figure><\/div>\n<div lang=\"en-AU\" style=\"background:#ffffff;border-left:5px solid #951b81;border-radius:0 16px 16px 0;padding:24px 28px;margin:8px 0 36px\"><p style=\"margin:0 0 4px;font-size:13px;font-weight:600;color:#951b81\">Good to know<\/p><h3 style=\"margin:0 0 14px;font-size:18px;font-weight:600;line-height:1.35;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">The testing methodology for material compatibility depends on:<\/h3><ul style=\"margin:0;padding:0\"><li style=\"display:flex;gap:12px;align-items:baseline;margin:0;padding:11px 0;border-top:1px solid #e5e4f2;font-size:15px;line-height:1.5;color:#17223c\"><span aria-hidden=\"true\" style=\"flex:0 0 7px;width:7px;height:7px;border-radius:50%;background:#951b81;position:relative;top:-2px\"><\/span><span>How the disinfectant is used<\/span><\/li><li style=\"display:flex;gap:12px;align-items:baseline;margin:0;padding:11px 0;border-top:1px solid #e5e4f2;font-size:15px;line-height:1.5;color:#17223c\"><span aria-hidden=\"true\" style=\"flex:0 0 7px;width:7px;height:7px;border-radius:50%;background:#951b81;position:relative;top:-2px\"><\/span><span>The number of test cycles to be performed<\/span><\/li><li style=\"display:flex;gap:12px;align-items:baseline;margin:0;padding:11px 0;border-top:1px solid #e5e4f2;font-size:15px;line-height:1.5;color:#17223c\"><span aria-hidden=\"true\" style=\"flex:0 0 7px;width:7px;height:7px;border-radius:50%;background:#951b81;position:relative;top:-2px\"><\/span><span>The medical device manufacturer requirements on the condition of the device after testing<\/span><\/li><\/ul><\/div>\n<div lang=\"en-AU\" style=\"margin:8px 0 28px\"><h3 style=\"margin:0 0 6px;font-size:19px;font-weight:600;line-height:1.35;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">Typical methods include:<\/h3><details open style=\"background:#ffffff;border-radius:14px;margin:0 0 10px\"><summary style=\"display:flex;align-items:center;gap:16px;padding:18px 20px;cursor:pointer\"><span style=\"display:inline-flex;align-items:center;justify-content:center;flex:0 0 36px;width:36px;height:36px;background:#951b81;border-radius:6.6px;color:#ffffff;font-weight:600;font-size:15px\">1<\/span><span style=\"flex:1 1 auto;font-size:17px;line-height:1.4;font-weight:600;color:#17223c\">Immersion studies<\/span><span aria-hidden=\"true\" style=\"flex:0 0 30px;width:30px;height:30px;border-radius:50%;border:1.5px solid #d9d8e8;color:#951b81;font-size:18px;line-height:27px;text-align:center\">+<\/span><\/summary><div style=\"padding:0 20px 20px\"><p style=\"margin:0;font-size:15px;line-height:1.7;color:#17223c\">This study involves submerging the device or material in the test solution for an extended period. The approach is often considered the gold standard, as it represents a worst-case exposure scenario. However, it may not always reflect actual clinical use conditions and is therefore not always the most appropriate method.<\/p><\/div><\/details><details style=\"background:#ffffff;border-radius:14px;margin:0 0 10px\"><summary style=\"display:flex;align-items:center;gap:16px;padding:18px 20px;cursor:pointer\"><span style=\"display:inline-flex;align-items:center;justify-content:center;flex:0 0 36px;width:36px;height:36px;background:#951b81;border-radius:6.6px;color:#ffffff;font-weight:600;font-size:15px\">2<\/span><span style=\"flex:1 1 auto;font-size:17px;line-height:1.4;font-weight:600;color:#17223c\">Wiping studies<\/span><span aria-hidden=\"true\" style=\"flex:0 0 30px;width:30px;height:30px;border-radius:50%;border:1.5px solid #d9d8e8;color:#951b81;font-size:18px;line-height:27px;text-align:center\">+<\/span><\/summary><div style=\"padding:0 20px 20px\"><p style=\"margin:0;font-size:15px;line-height:1.7;color:#17223c\">This study is designed to replicate real-life use of disinfectant wipes. They allow for the evaluation of both material compatibility and the impact of the mechanical action involved in wiping.<\/p><\/div><\/details><details style=\"background:#ffffff;border-radius:14px;margin:0 0 10px\"><summary style=\"display:flex;align-items:center;gap:16px;padding:18px 20px;cursor:pointer\"><span style=\"display:inline-flex;align-items:center;justify-content:center;flex:0 0 36px;width:36px;height:36px;background:#951b81;border-radius:6.6px;color:#ffffff;font-weight:600;font-size:15px\">3<\/span><span style=\"flex:1 1 auto;font-size:17px;line-height:1.4;font-weight:600;color:#17223c\">Wrapping (wet-patch) studies<\/span><span aria-hidden=\"true\" style=\"flex:0 0 30px;width:30px;height:30px;border-radius:50%;border:1.5px solid #d9d8e8;color:#951b81;font-size:18px;line-height:27px;text-align:center\">+<\/span><\/summary><div style=\"padding:0 20px 20px\"><p style=\"margin:0;font-size:15px;line-height:1.7;color:#17223c\">This study involves wrapping a material sample or device in a wipe impregnated with the disinfectant chemistry. It is particularly useful for wipe-based products or when application by wiping is intended but performing a full wiping study is not practical.<\/p><\/div><\/details><\/div>\n<span lang=\"en-AU\" id=\"what-is-efficacy-validation\" aria-hidden=\"true\" style=\"display:block;position:relative;top:-160px;height:0;margin:0;padding:0;visibility:hidden\"><\/span><h2 lang=\"en-AU\" style=\"color:#17223c;max-width:none;width:auto\">What is efficacy validation?<\/h2>\n<p lang=\"en-AU\">Efficacy validation refers to the evidence demonstrating that a reusable medical device can be safely reprocessed using specific products, which include cleaning agents and\/or disinfectants, resulting in the device being ready for safe use.<\/p>\n<div lang=\"en-AU\" style=\"background:#e5e4f2;border-radius:20px;padding:26px 28px 24px;margin:16px 0 36px\"><div style=\"display:flex;flex-wrap:wrap;gap:12px\"><div style=\"flex:1 1 260px;padding:20px;border-radius:14px;background:#ffffff\"><h3 style=\"margin:0 0 12px;font-size:16px;font-weight:600;line-height:1.4;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">Disinfectant manufacturers<\/h3><p style=\"margin:0 0 10px;font-size:14.5px;line-height:1.6;color:#17223c\">Disinfectant manufacturers are responsible for performing testing in accordance with relevant standards.<\/p><p style=\"margin:0;font-size:14.5px;line-height:1.6;color:#17223c\">Testing needs to demonstrate both the efficacy of their products and their material compatibility to support any microbiological claims.<\/p><\/div><div style=\"flex:1 1 260px;padding:20px;border-radius:14px;background:#ffffff\"><h3 style=\"margin:0 0 12px;font-size:16px;font-weight:600;line-height:1.4;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">Medical device manufacturers<\/h3><p style=\"margin:0 0 10px;font-size:14.5px;line-height:1.6;color:#17223c\">Medical device manufacturers are also responsible for conducting efficacy validation on their specific devices.<\/p><p style=\"margin:0;font-size:14.5px;line-height:1.6;color:#17223c\">This includes verifying that selected reprocessing products and methods are effective for the device, as well as providing clear, validated instructions to end users to ensure safe use for subsequent patients.<\/p><\/div><\/div><\/div>\n<figure lang=\"en-AU\" style=\"margin:8px 0 36px;padding:0\"><img decoding=\"async\" src=\"https:\/\/tristel.com\/wp-content\/uploads\/2026\/06\/Untitled-design-2.png\" alt=\"Healthcare worker wiping an ultrasound probe beside an ultrasound machine\" style=\"display:block;width:100%;height:clamp(220px,42vw,400px);object-fit:cover;object-position:center 42%;margin:0;border-radius:20px;border:0;box-shadow:none;background:#e5e4f2\"\/><\/figure>\n<div lang=\"en-AU\" style=\"background:#ffffff;border-left:5px solid #951b81;border-radius:0 16px 16px 0;padding:24px 28px;margin:8px 0 28px\"><h3 style=\"margin:0 0 10px;font-size:18px;font-weight:600;line-height:1.35;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">ISO 17664:2021<\/h3><p style=\"margin:0 0 18px;font-size:15px;line-height:1.65;color:#17223c\">Efficacy validation testing is governed by ISO 17664:2021, \u201cProcessing of health care products \u2014 Information to be provided by the medical device manufacturer for the processing of medical devices.\u201d<\/p><div style=\"display:flex;flex-wrap:wrap;align-items:center;gap:12px 18px\"><div aria-hidden=\"true\" style=\"flex:0 0 auto;display:flex;align-items:center;gap:10px\"><span style=\"display:inline-block;padding:10px 16px;border-radius:12px;background:#e5e4f2;font-size:15px;font-weight:600;color:#17223c\">1 automated<\/span><span style=\"font-size:18px;font-weight:600;color:#951b81\">+<\/span><span style=\"display:inline-block;padding:10px 16px;border-radius:12px;background:#e5e4f2;font-size:15px;font-weight:600;color:#17223c\">1 manual<\/span><\/div><p style=\"flex:1 1 260px;margin:0;font-size:15px;line-height:1.6;color:#17223c\">This standard specifies that medical device manufacturers are responsible for validating at least one automated and one manual reprocessing method for their reusable devices.<\/p><\/div><\/div>\n<p lang=\"en-AU\">These validations are typically performed through simulated-use testing. The validated processes are then defined as the recommended reprocessing methods and included in the device&#8217;s instructions for use.<\/p>\n<div lang=\"en-AU\" style=\"background:#e5e4f2;border-radius:20px;padding:26px 28px 18px;margin:16px 0 36px\"><h3 style=\"margin:0 0 6px;font-size:19px;font-weight:600;line-height:1.35;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">Simulated-use testing<\/h3><p style=\"margin:0 0 20px;font-size:14.5px;line-height:1.6;color:#454861\">This testing method is designed to replicate a real-life reprocessing cycle.<\/p><div style=\"position:relative;padding:0 0 12px 54px\"><span aria-hidden=\"true\" style=\"position:absolute;left:17px;top:40px;bottom:-12px;width:2px;background:#951b81;opacity:0.25\"><\/span><span style=\"display:inline-flex;align-items:center;justify-content:center;width:36px;height:36px;background:#951b81;border-radius:6.6px;position:absolute;left:0;top:4px;color:#ffffff;font-size:14px;font-weight:600\">1<\/span><div style=\"background:#ffffff;border-radius:12px;padding:13px 16px;font-size:15px;line-height:1.6;color:#17223c\"><strong style=\"display:block;font-weight:600;margin:0 0 2px\">Contaminate and reprocess<\/strong>In this process, a medical device is deliberately contaminated with representative microorganisms and organic soil before undergoing the decontamination procedure.<\/div><\/div><div style=\"position:relative;padding:0 0 12px 54px\"><span style=\"display:inline-flex;align-items:center;justify-content:center;width:36px;height:36px;background:#951b81;border-radius:6.6px;position:absolute;left:0;top:4px;color:#ffffff;font-size:14px;font-weight:600\">2<\/span><div style=\"background:#ffffff;border-radius:12px;padding:13px 16px;font-size:15px;line-height:1.6;color:#17223c\"><strong style=\"display:block;font-weight:600;margin:0 0 2px\">Evaluate<\/strong>Following reprocessing, the device is evaluated using defined markers, such as residual protein to assess cleaning efficacy, or remaining microbial contamination, to assess disinfection efficacy.<\/div><\/div><\/div>\n<figure lang=\"en-AU\" style=\"margin:0 0 36px;padding:0\"><img decoding=\"async\" src=\"https:\/\/tristel.com\/wp-content\/uploads\/2025\/09\/Microorganisms-resistance-scaled.jpeg\" alt=\"Gloved hand holding an agar plate with microbial colonies in a laboratory\" style=\"display:block;width:100%;height:clamp(160px,24vw,230px);object-fit:cover;object-position:center 42%;margin:0;border-radius:20px;border:0;box-shadow:none;background:#e5e4f2\"\/><\/figure>\n<p lang=\"en-AU\">In some cases, regulatory standards define the test parameters. Where no harmonised specifications or standards exist, appropriate parameters must be established to ensure a scientifically sound validation of the reprocessing process.<\/p><div lang=\"en-AU\" style=\"background:#ffffff;border-radius:20px;padding:24px 28px 14px;margin:16px 0 28px\"><h3 style=\"margin:0 0 14px;font-size:18px;font-weight:600;line-height:1.35;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">When defining these parameters, the following aspects should be considered:<\/h3><ul style=\"margin:0;padding:0\"><li style=\"display:flex;gap:12px;align-items:baseline;margin:0;padding:11px 0;border-top:1px solid #e5e4f2;font-size:15px;line-height:1.5;color:#17223c\"><span aria-hidden=\"true\" style=\"flex:0 0 7px;width:7px;height:7px;border-radius:50%;background:#951b81;position:relative;top:-2px\"><\/span><span>The intended use and clinical application of the medical device<\/span><\/li><li style=\"display:flex;gap:12px;align-items:baseline;margin:0;padding:11px 0;border-top:1px solid #e5e4f2;font-size:15px;line-height:1.5;color:#17223c\"><span aria-hidden=\"true\" style=\"flex:0 0 7px;width:7px;height:7px;border-radius:50%;background:#951b81;position:relative;top:-2px\"><\/span><span>The actual method of disinfectant application in clinical practice<\/span><\/li><li style=\"display:flex;gap:12px;align-items:baseline;margin:0;padding:11px 0;border-top:1px solid #e5e4f2;font-size:15px;line-height:1.5;color:#17223c\"><span aria-hidden=\"true\" style=\"flex:0 0 7px;width:7px;height:7px;border-radius:50%;background:#951b81;position:relative;top:-2px\"><\/span><span>The selection of test soil locations, taking into account device design features, including worst-case or hard-to-clean areas such as joints, crevices, or ridges<\/span><\/li><\/ul><\/div>\n<span lang=\"en-AU\" id=\"what-makes-chemistry-compatible-with-a-medical-device\" aria-hidden=\"true\" style=\"display:block;position:relative;top:-160px;height:0;margin:0;padding:0;visibility:hidden\"><\/span><h2 lang=\"en-AU\" style=\"color:#17223c;max-width:none;width:auto\">What makes chemistry compatible with a medical device?<\/h2>\n<p lang=\"en-AU\">All disinfectant chemistries interact with materials to some extent. When the properties of the material and the disinfectant are well aligned, the material will remain stable over repeated reprocessing cycles.<\/p><p lang=\"en-AU\">However, incompatibility can arise when certain chemistries react adversely with the material. For example:<\/p>\n<div lang=\"en-AU\" style=\"margin:8px 0 28px\"><div style=\"display:flex;flex-wrap:wrap;gap:12px;margin:0 0 22px\"><div style=\"flex:1 1 260px;padding:20px 22px;border-radius:16px;background:#17223c\"><p aria-hidden=\"true\" style=\"margin:0;display:flex;flex-wrap:wrap;align-items:center;gap:8px;font-size:15px;font-weight:600;color:#ffffff\"><span style=\"padding:4px 12px;border-radius:999px;background:#ffffff;color:#17223c\">Some polymers<\/span><span style=\"color:#c4c2d0\">+<\/span><span style=\"padding:4px 12px;border-radius:999px;border:1px solid #686f80;color:#ffffff\">Alcohols<\/span><\/p><p style=\"margin:14px 0 0;font-size:14.5px;line-height:1.55;color:#dcdee2\">Some polymers may be sensitive to alcohols, leading to <strong style=\"font-weight:600;color:#ffffff\">stress cracking or embrittlement<\/strong>.<\/p><\/div><div style=\"flex:1 1 260px;padding:20px 22px;border-radius:16px;background:#17223c\"><p aria-hidden=\"true\" style=\"margin:0;display:flex;flex-wrap:wrap;align-items:center;gap:8px;font-size:15px;font-weight:600;color:#ffffff\"><span style=\"padding:4px 12px;border-radius:999px;background:#ffffff;color:#17223c\">Low-grade metals<\/span><span style=\"color:#c4c2d0\">+<\/span><span style=\"padding:4px 12px;border-radius:999px;border:1px solid #686f80;color:#ffffff\">Oxidising agents<\/span><\/p><p style=\"margin:14px 0 0;font-size:14.5px;line-height:1.55;color:#dcdee2\">Low-grade metals may be susceptible to oxidising agents, which can cause <strong style=\"font-weight:600;color:#ffffff\">discolouration or corrosion<\/strong>.<\/p><\/div><\/div><p style=\"margin:0;font-size:16px;line-height:1.7;color:#1c1c1c\">Other factors that can influence compatibility include contact time, temperature, frequency of exposure and the method of application.<\/p><\/div>\n<p lang=\"en-AU\">For this reason, material compatibility must be assessed and validated under realistic use conditions to ensure that the medical device maintains its functional performance, structural integrity and safety throughout its intended lifetime.<\/p>\n<span lang=\"en-AU\" id=\"the-power-of-chlorine-dioxide\" aria-hidden=\"true\" style=\"display:block;position:relative;top:-160px;height:0;margin:0;padding:0;visibility:hidden\"><\/span><h2 lang=\"en-AU\" style=\"color:#17223c;max-width:none;width:auto\">The power of chlorine dioxide<\/h2>\n<p lang=\"en-AU\">Tristel&#8217;s proprietary chlorine dioxide (ClO<sub>2<\/sub>) is generated through the reaction of sodium chlorite with citric acid and is effective against a broad range of pathogens at low concentrations. ClO<sub>2<\/sub> has a lower oxidation potential compared to other commonly used disinfectants such as peracetic acid, hydrogen peroxide and aqueous chlorine, making it less aggressive toward materials.<\/p>\n<div lang=\"en-AU\" aria-hidden=\"true\" style=\"background:#ffffff;border-radius:20px;padding:24px 26px 24px;margin:8px 0 28px\"><h3 style=\"margin:0 0 18px;font-size:18px;font-weight:600;line-height:1.35;color:#17223c;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">Oxidation potential<\/h3><div style=\"display:flex;flex-wrap:wrap;gap:12px;align-items:stretch\"><div style=\"flex:1 1 200px;padding:18px;border-radius:14px;background:#CCFF00\"><p style=\"margin:0 0 6px;font-size:12px;font-weight:600;letter-spacing:0.08em;text-transform:uppercase;color:#17223c\">Lower<\/p><p style=\"margin:0 0 4px;font-size:40px;font-weight:600;line-height:1;color:#17223c\">ClO<sub style=\"font-size:0.45em\">2<\/sub><\/p><p style=\"margin:0;font-size:15px;font-weight:500;line-height:1.35;color:#17223c\">Chlorine dioxide<\/p><\/div><div style=\"flex:2 1 300px;padding:18px;border-radius:14px;background:#e5e4f2\"><p style=\"margin:0 0 10px;font-size:12px;font-weight:600;letter-spacing:0.08em;text-transform:uppercase;color:#454861\">Higher<\/p><div style=\"display:flex;flex-wrap:wrap;gap:8px\"><span style=\"padding:6px 12px;border-radius:999px;background:#ffffff;font-size:14px;font-weight:500;color:#17223c\">Peracetic acid<\/span><span style=\"padding:6px 12px;border-radius:999px;background:#ffffff;font-size:14px;font-weight:500;color:#17223c\">Hydrogen peroxide<\/span><span style=\"padding:6px 12px;border-radius:999px;background:#ffffff;font-size:14px;font-weight:500;color:#17223c\">Aqueous chlorine<\/span><\/div><\/div><\/div><\/div>\n<p lang=\"en-AU\">As a result, chlorine dioxide generally demonstrates good compatibility with a wide range of materials, including many plastics, rubbers and adhesives commonly used in medical devices.<\/p>\n<div lang=\"en-AU\" style=\"position:relative;overflow:hidden;background-color:#17223c;background-image:linear-gradient(90deg,rgba(23,34,60,1) 0%,rgba(23,34,60,0.92) 45%,rgba(23,34,60,0.35) 100%),url(&apos;https:\/\/tristel.com\/wp-content\/uploads\/2026\/09\/Tristel_Academy_TechPattern_WHITE-scaled.png&apos;);background-size:auto,600px auto;background-position:0 0,right top;background-repeat:no-repeat,repeat;border-radius:20px;padding:28px;margin:8px 0 36px;display:flex;flex-wrap:wrap;align-items:center;gap:20px 32px\"><div style=\"flex:1 1 320px;min-width:0\"><h3 style=\"margin:0 0 8px;font-size:21px;font-weight:600;line-height:1.3;color:#ffffff;font-family:inherit;letter-spacing:0;text-transform:none;max-width:none\">Unsure if your medical device is compatible with Tristel products?<\/h3><p style=\"margin:0 0 20px;font-size:15px;line-height:1.65;color:#e3e4e8\">Use our device compatibility tracker! Simply enter the make and model to find out.<\/p><a href=\"https:\/\/tristel.com\/au-en\/product-compatibility\" target=\"_blank\" rel=\"noopener\" aria-label=\"Open the Device Compatibility Tracker (opens in a new tab)\" style=\"display:inline-block;padding:12px 24px;border-radius:999px;background:linear-gradient(90deg,rgb(149,27,129),rgb(215,11,82));color:#ffffff;font-size:15px;font-weight:600;text-decoration:none\">Device Compatibility Tracker<\/a><\/div><div aria-hidden=\"true\" style=\"flex:0 0 240px;width:240px;max-width:100%;height:164px;margin:0 auto;background-image:url(&apos;https:\/\/tristel.com\/wp-content\/uploads\/2026\/10\/Untitled-design-3.svg&apos;);background-size:437px auto;background-position:0 0;background-repeat:no-repeat\"><\/div><\/div>\n<details lang=\"en-AU\" style=\"border-top:1px solid #d9d8e8;padding-top:16px;margin:8px 0 24px\"><summary style=\"cursor:pointer;font-size:14px;font-weight:600;color:#17223c\">References and further reading <span style=\"color:#951b81\">(3)<\/span><\/summary><ol style=\"margin:12px 0 0;padding-left:20px;font-size:13px;line-height:1.7;color:#454861\"><li style=\"margin:0 0 6px\"><a href=\"https:\/\/www.aami.org\/standard\/aami-tir122020-r2023-pdf\/\" style=\"color:#17223c;text-decoration:underline\">Association for the Advancement of Medical Instrumentation (2020, reaffirmed 2023). AAMI TIR12:2020 (R2023): Designing, testing, and labeling medical devices intended for processing by health care facilities\u2014A guide for device manufacturers.<\/a><\/li><li style=\"margin:0 0 6px\"><a href=\"https:\/\/www.en-standard.eu\/bs-en-14885-2022-chemical-disinfectants-and-antiseptics-application-of-european-standards-for-chemical-disinfectants-and-antiseptics\/\" style=\"color:#17223c;text-decoration:underline\">European Committee for Standardization (2022). EN 14885:2022: Chemical disinfectants and antiseptics\u2014Application of European standards for chemical disinfectants and antiseptics.<\/a><\/li><li style=\"margin:0 0 6px\"><a href=\"https:\/\/www.astm.org\/d0543-21.html\" style=\"color:#17223c;text-decoration:underline\">ASTM International (2021). ASTM D543\u201121: Standard practices for evaluating the resistance of plastics to chemical reagents.<\/a><\/li><\/ol><\/details>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>IPC in Practice In this article you&#8217;ll learn What is material compatibility? What is efficacy validation? What makes chemistry compatible with a medical device? The power of chlorine dioxide When [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":11696,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","inline_featured_image":false,"footnotes":""},"categories":[145],"tags":[],"media_type":[149],"portfolio":[],"discipline":[],"class_list":["post-11010","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ipc-in-practice","media_type-educational-insights"],"acf":[],"featured_media_global":[],"_links":{"self":[{"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/posts\/11010","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/comments?post=11010"}],"version-history":[{"count":0,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/posts\/11010\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/media\/11696"}],"wp:attachment":[{"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/media?parent=11010"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/categories?post=11010"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/tags?post=11010"},{"taxonomy":"media_type","embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/media_type?post=11010"},{"taxonomy":"portfolio","embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/portfolio?post=11010"},{"taxonomy":"discipline","embeddable":true,"href":"https:\/\/tristel.com\/au-en\/wp-json\/wp\/v2\/discipline?post=11010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}